search
< >

Verniflam® AITHON PV33 - Transparent and matte intumescent varnish

Exclusively used with the Verniflam® AITHON F3 or Verniflam® AITHON F3A topcoat, Verniflam® AITHON PV33 intumescent is an aqueous fireproof protective coating for the fire classification of wood and wood-derived materials, inside public buildings, on areas such as walls or ceilings, not subject to mechanical stress. Verniflam® AITHON PV33 is not suitable for floors or stairs, for example.

Translucent, colourless (non-yellowing). It is also suitable for improving the fire resistance of wooden elements.

Any application of a varnish must be subject to a preliminary test in order to verify compatibility with the substrate.

To date, the Verniflam® AITHON PV33 reaction to fire documents only concern use with Verniflam® AITHON F3, Verniflam® AITHON F3A or a non-declassifying top coat as a finishing coat as described in the Classification Reports.

Packaging of 3 kg, 7.5 kg or 20 kg

We also offer the application of our intumescent solutions in workshops, on your supports, do not hesitate to contact us for any request or quote.

PACKAGING
VERNIFLAM® PV33

Paiement sécurisé avec votre compte Paypal ou votre carte de paiement

Verniflam® Aithon PV33 is only used in combination with Top-Coat Verniflam® Aithon F3 or Verniflam® Aithon F3A.

Verniflam® Aithon PV33 intumescent is a transparent, water-based, fire-retardant protective coating that forms an intumescent thermal insulation layer when heated. It delays the spread of fire and reduces the flammability of wood and wood derivatives. It is also a non-declassifying solution.

With a certain weight, the fire resistance of the elements is also improved.

Verniflam® Aithon PV33 intumescent highlights the aesthetics and interior architecture of wooden constructions and thus offers architects and project managers an attractive solution.

Fire behaviour

Reaction to fire:

  • Classified B-s1,d0 according to standard EN 13501-1.
  • Classification report No. 18-RC-33 at FCBA.
  • Classified C-s1,d0 according to standard EN13501-1
  • Classification report No. 19-RC-57 at FCBA

Fire resistance:

  • Provides resistance from R15 to R60 according to standards ENV 13381-7 and EN 13501-2.
  • Classification report No. CR-059-13 at FIRES.

A verification gauge is offered from 1,000 € excluding VAT of purchase in our VERNIFLAM® range.

WEBPV33020

Data sheet

Fire reaction classification
Euroclasse B
Material
Bois

Specific References

Download

FT Verniflam® PV33

Download (205.85k)